Chiller AquaEdge® 23XRV
รายละเอียดสินค้า
Performance Features
- IPLV up to 0.299
- Chlorine-free HFC-134a refrigerant
- Full-load kW/Ton down to 0.60
- Tri-rotor Screw compressor
- Hermetically sealed compressor motor
- Low inrush current
- Economizer type cooler
- Superior refrigerant oil management/condensing operation
- 0.025 in (0.635 mm) internally and externally enhanced copper tubing
- Cooler and condenser rated at 150 psig (1034 kPa) and 300 psig (2068 kPa)
- LCD control display
- Multi-language display screen
- Power demand assignment via Carrier Comfort Network® (CCN) communication link
Reliability Features
- Low voltage control circuit
- Hermetically sealed compressor motor
- Maintenance Features
- Comprehensive, password-protected service menu with built-in fault diagnosis, troubleshooting, and suggested corrective action for pre-set alarms
- Alarm and notification files stored with date and time stamps in memory
- Setup backup with non-volatile memory
- Refrigerant isolation valves for in-chiller refrigerant storage (Factory-installed option)
Installation Features
- Single-point electrical connection
- Can be disassembled and reassembled
- Factory-installed VFD with single-point connection
- Small base area
ราคาต้องสอบถาม
Type:
Regular
Color
Brown
Material
Cotton, Jeans
Brand
Reebook
Performance Features
- IPLV up to 0.299
- Chlorine-free HFC-134a refrigerant
- Full-load kW/Ton down to 0.60
- Tri-rotor Screw compressor
- Hermetically sealed compressor motor
- Low inrush current
- Economizer type cooler
- Superior refrigerant oil management/condensing operation
- 0.025 in (0.635 mm) internally and externally enhanced copper tubing
- Cooler and condenser rated at 150 psig (1034 kPa) and 300 psig (2068 kPa)
- LCD control display
- Multi-language display screen
- Power demand assignment via Carrier Comfort Network® (CCN) communication link
Reliability Features
- Low voltage control circuit
- Hermetically sealed compressor motor
- Maintenance Features
- Comprehensive, password-protected service menu with built-in fault diagnosis, troubleshooting, and suggested corrective action for pre-set alarms
- Alarm and notification files stored with date and time stamps in memory
- Setup backup with non-volatile memory
- Refrigerant isolation valves for in-chiller refrigerant storage (Factory-installed option)
Installation Features
- Single-point electrical connection
- Can be disassembled and reassembled
- Factory-installed VFD with single-point connection
- Small base area